History of FlashIt!32 ===================== Rel 02.73.15 ==> Rel 02.74.00 ----------------------------- Fix [FLASHIT-65] : Flash of Lables only in Maxxis not possible Fix [FLASHIT-63] : Merge of Lables only for Maxxis not possible New : FlashIt!.exe is now signed. Change [KYODO] : New Company Setup and Paths Rel 02.73.14 ==> Rel 02.73.15 ----------------------------- Fix [FLASHIT-62] : Wrong installation dir Rel 02.73.12 ==> Rel 02.73.14 ----------------------------- Fix [FLASHIT-60] : Need chap authentication support for pr5220 Rel 02.73.11 ==> Rel 02.73.12 ----------------------------- New : Add flashinfo.xml to Maxxis-Images to track flashit-version in service-report New : Add Maxxis-Supporting files images/*.gif,xml/*.xml,help/*.help,lang/*.mo by general rule Rel 02.73.10 ==> 02.73.11 ----------------------- New [FLASHIT-55] : Flash api-*.mo and operation-*.mo if selected Rel 2.73.09 ==> Rel 02.73.10 ----------------------- New : Support for PR5500 Maxxis 4 New : Check for valid PR1750 license in application before Flash/Merge Rel 2.73.08 ==> Rel 02.73.09 ----------------------- Fix [FLASHIT-51] : xml and help files for Maxxis5 projects were not properly processes, when flashing/merging P32 file Rel 2.73.07 ==> Rel 02.73.08 ----------------------- Change : Include project name into Labels romfs-name (if available) Rel 2.73.06 ==> Rel 02.73.07 ----------------------- Fixed : Problems flashing applications/lables for PR5900-r01 Rel 2.73.03 ==> Rel 02.73.06 ----------------------- Changed : support for r00/r01 in PR5900 Maxxis Rel 2.73.0 ==> Rel 02.73.03 ----------------------- New : support for PR5900 Maxxis Rel 2.72.0 ==> Rel 02.73.00 ----------------------- New : Support for updating firmware/bios of PR5220/PR5230/PR5410 Rel 2.70.0 ==> Rel 02.72.00 ----------------------- Fixed : Problems with certain USB-Serial converters Fixed : Program termination on to long label list Changed : Many extensions for sartorius internal use. Rel 2.60.2 ==> Rel 2.70.0 ----------------------- New : Added support for flashing labels into X3-PR5410 Rel 2.60.1 ==> Rel 2.60.2 ----------------------- Fixed : #0972 missing dialog for flashing bios in CombicsPro Fixed : #1381 CombicsPro applications could not be opened by doubleclick Changed : #1269 dont close progress-window on error Changed : use windows-api for serial com timeouts Changed : use APPDATA for safe settings New : added support for production (for internal use only) Rel 2.60.0 ==> Rel 2.60.1 ----------------------- Fixed : Minor timeout updated for X-Series Rel 2.26.x ==> Rel 2.60 ----------------------- New : Support for Combics Pro Rel 2.26.1 ==> Rel 2.26.2 ------------------------- Change : Original message now "ORIGINAL SAG HH" New : Option to disable MD5-Checks Removed : Internal test code for W&M-BIOS Rel 2.26.0 ==> Rel 2.26.1 ------------------------- Fixed: Workaround for bug with EthernetFlash over PR1713/14 Rel 2.24.0 ==> Rel 2.26.0 ------------------------- New: Support for W&M-BIOS PR8901/10 Rel 2.22.1 ==> Rel 2.24.0 ------------------------- New: Support for flashing via ethernet (Requires BIOS 3.10 or better) New: Flashing blocks checked by MD5 signature New: Enhanced security when flashing BIOS Fixed: Flash of firmware for ethernet cards Change: Added some timeouts to serial communication Fix: Detect [Stop][Exit] on several hardware Fix: Flash of ethernet card Rel 2.20.4 ==> Rel 2.22.1 ------------------------- New: Support of X4 Devices Change: Now uses CHM as helpfile New: BatchMerge (for internal use only) Rel 2.20.3 ==> Rel 2.20.4 ------------------------- New: Check files shows a busy-bee and a message when done Fixed: Merging or Flashing projects exceeding the small memory unit of PR1730 corrupted firmware. (Introduced with 2.20.3) Fixed: open comport failed, when port from FlashIt!.ini didn't exist on PC Added: Allow load into ram (for internal use only) Change: Show Filename first in ListBoxes for ease of use Rel 2.20.2 ==> Rel 2.20.3 ------------------------- New: Ability to read compressed hex files (*.hez) New: Additional W&M Authorization for trained personal Fixed: Wrong language was flashed, if Language-Name had special characters. Fixed: BCC Calculation for PR1730 Projects exceeding 512k FlashProm (Projects merged with older Versions of FlashIt! should be once more) New: Prepared flashing of PR5210 Rel 2.20.1 ==> Rel 2.20.2 ------------------------- New: Option Check Files removes files from combo boxes, that are not available any more New: Check for Flash-Size in PR1730 and issue an error, if project will not fit Change: Deny Flash of X5-BIOS into Device with old bios New: Flashing Original GWT in factory/develop Rel 2.20 ==> Rel 2.20.1 ------------------------- Change: Allow Flash of old BIOS without Hardware-Code in PR1713/00 Change: Deny Flash of X5-BIOS into Device with old bios Rel 2.06 ==> Rel 2.20 ------------------------- New: Support for .LBLS and .LTXT files for X5-Projects New: Load and save of FlashIt Projects (.FPRJ) New: Check for project sizes New: Check of CAL-Switch in PR1713 New: Separate progress window New: Store Flash Date in PR1713 New: Store Flash User-Code in PR1713 (Only authorized users) New: Allow Drag'n'Drop of files into running FlashIt! New: Detect available com-ports at startup New: Allow user to use HighSpeed (with a warning) New: Select Hardware code (Only authorized users)