New in Version: 3.01.08 ----------------------- * Fixed: Start functionality via fieldbus and OPC. New in Version: 3.01.07 ----------------------- * Fixed: Print error with character $Ao * Fixed: Included new version of library New in Version: 3.01.06 ----------------------- * Fixed: Batch mode A1 New in Version: 3.01.05 ----------------------- * Fixed: EW-Command LR (READ), selected report will be deleted after read. New in Version: 3.01.04 ----------------------- * Fixed: fixed labels with actual version of NLE. New in Version: 3.01.03 ----------------------- * Repair: keyboard buffer is cleared before showing main menue New in Version: 3.01.03 ----------------------- * Repair: the I/O of PR1713/13 can now be assigned (SETUP->CONFIG) New in Version: 3.01.02 ----------------------- * Repair: String 'PR1740' changed to 'PR8400'. * changed error text 'analog error' to 'invalid weight' New in Version: 3.01.01 ----------------------- * Repair: Remote start of recipes: unit of set point is now lb when unit of weighing point is lb. New in Version: 3.01.00 ----------------------- * Application is build with PR1750 version 3.00.00 !!!!!! * Repair: Remote start of recipes is now possible with ProBatch+. New in Version: 3.00.01 ---------------------- * Repair: Softkey 'Abort'is now enabled for batch mode D1 and D2 instead of 'Return' New in Version: 3.00.0 ---------------------- * Repair: No old EW-Com commands are accepted * Repair: batch report --> unit of D3 component was weight (e.g. kg) * D1 and D2 components are displayed with the same default display layout L1: LNR KompName L2: Dx D Weight the display may be switched using the 'More' key to show Setpoint instead of difference weight in the second line. Also 2 other (unchanged) display modes are available via 'More' or '<-' '->' keys. Other than D1/D2 components use a 'persistant' display mode - that is the display mode is kept the same across different lines and even recipies. This mechanism has been saved - except for D1/D2. New in Version: 2.20.1 ---------------------- * Repair: Fieldbus functions of application New in Version: 2.20 ---------------------- * No message DB-Error after PR1740-download with too long RECname[20] * Report to APPLI&PROLOG now usable (means: local print of Report is possible and PR1740 receives Report also to get ready) * additional Remote-Start from PR1713 via PR1740 for Recipe and Mainrecipe (use PR1741/41_Licence) usabel via Serial or Ethernet-Connection and with PR1740 < R6.0 to >/= R6.x(DB-STRUCTURE-change in 174007*.mdb) Hint: if not a german and english WINDOWS-Version a SQL-Request will not give recommend answer:wahr or true * if manual operator enters SETPOINT > FSD, batch is splitted into cycles. + Confim menu * check free memory space, before Batch is started, new Mat and new Recipe should be created. Leave additional space 3kbyte for RecoverIt. Reports > 10 may stay in device (used when set: Report to COMM) * Bit 1319 aborts all cycles of a batch * new DB-error message if recipe-head/line or Matline could not be added (DB put not possible). * A1, A2 component: PR1740 sends always a "value" undependend to scale x.xxx u6 in Tol-field. Material editor accepts and transforms this PR1740-unit, not PR1713-unit. * No SPM-in parameter (enable) for D6 and D7 batch mode in component editor. * Download PR1740-recipe with 20char-ID length does not generate >DB-Error< anymore on start New in Version: 2.12 ---------------------- * new display modes during recipe status display * no config-data in seperate DB-table any more New in Version: 2.02.2 ---------------------- * repair: system bit %MX429 used for spontaneous communication telegrams from old EW-Com is triggered again * new protection function. Bit %MX 1330: prohibit operater to enter any component, recipe or clear consumption or production New in Version: 2.02.1 ---------------------- * repair: analog output via A1-component * readout for i/o-field 1024-1279 via fieldbus. Used Read/write-Address: 50...57 will read/write 32 bit each. * binary coded recipe start via digital inputs: %MB 165; %MX 1320..1327 (LSB->1327). Start with %MX 1312 * new SPM-bits on fixed address for DDE access: %MX 1816..1821. Start recipe. New in Version: 2.02 ---------------------- * adaption for Firmware with free configurable type of weighing point. If WP-A is configured as XBPI- of fieldbus-WP, the WP may not be ready. The application will wait in coldstart program (AUTO) with operator menue. Coldstart program AUTO may be aborted because WP-A may be external WP which is not ready. Error message: "Error in WP-A", "Retry $03 $03Abort" A aborted coldstart initialisation of the application must be repeated. Program 'START' and 'CONFIG' will display: "Init. not ready","Make cold start!" The PLC program does not run until the coldstart initialisation of the application is done. * Addition for dosing phase: check if the target of dosing is greater FSD for dosing mode B1, B2 and B3; ->Error message 3. This check is deactivated on default setting. It can be activated by setting 1 to SPM address MB 317: USINT. By fieldbus the check can be activated on function address 125. With this address, the dosing mode is set in the lowest byte of the DINT (xxxxxxFF). The new check mode can be set in the second byte of the DINT (xxxx01xx). New in Version: 2.0 --------------------- * free konfiguratable i/o * Option with i/o on DIOS card * Option konfigurable reports with "nice lable express" * no function counting scale and fixtare anymore * changes in menues and texts New in Version: 1.12.2 --------------------- * PR1740 has downloaded the recipe and the unit of the recipe setpoint will show "???". This wrong setpoint is detected and set to 0 with a valid unit. New in Version: 1.12.1 --------------------- * When a recipe is started by PR1740 the message "PR1740 active" is displayed, as long as the recipe is running. No visualisation, nor recipe control is done. New in Version: 1.12 --------------------- * Old EW-communication commands done in application. See list: * Configuration of analog output (like PR1720) * Changed addresses for phase interface access!! Changes from App 1.08a to App 1.10 ---------------------------------- * Fieldbus interface. See specification! * Additional function for digital recipe start. If a setpoint is given in the configuration, it is taken from there and not from the recipe table. Equal to manual start. * The setup parameter for selecting the printer device has moved from 'config' (application) to 'Software Parameter' (firmware). * Repair: Recipe was line not deleted if recipe is deleted * PLC extended for I/O card PR1713_07 and PR1713_15 Supported cards by now: OPTION#PR1713_06 analog input OPTION#PR1713_07 analog input and output OPTION#PR1713_12 digital I/O Type: 4+4 OPTION#PR1713_15 Relais I/O Type: 4+4 OPTION#PR1713_17 digital I/O Type: 6+8 (Marini) Changes from App 1.08 to App 1.08a ---------------------------------- * Repair only Changes from App 1.06 to App 1.08 ---------------------------------- * Repair: PRODUCTION TABLE will be deleted and not added to DBase no more DBase overflow due to stand alone batching * On all printouts: timeout if seriel line is not ready for send out. * Additional material parameters could be entered if the dosing mode is not a standard mode (> two character eg.: 'B1_CYCLE') * Repair of printer queue. Print reports may remain on DBase when printout is blocked. Changes from App 1.04 to App 1.06 ---------------------------------- * Configurable weighing printout. * A recipe start by communication (e.g. PR1740) will be detected if the programm 'PROD' is active. Then the display switches to status display. * Manual edit of counting scale calibration * Show difference weight while batching manual component * Repair: if recipe start by digital input and no recipe number is selected, 'database error' was displayed. Changes from App 1.02 to App 1.04 ---------------------------------- * An external weighingpoint (PR1720) on Interbus-S is implemented * Batchreport printout: Alarmflags in are decoded to clear text * material printout: unnecessary string behind component name deleted * double key pressing -> single key pressing below the menue structure 'Report'; 'Prodct'. Only when licence /20 and not licence /21. Changes from App 1.00 to App 1.02: ---------------------------------- * The recipe start procedure stores the last used setpoint for each recipe. * new configuration parameter Setup / Config / start recipe now? If this parameter is set, an inquiry before the recipe start is done. This could also be used to enter an setpoint for this recipe with no need to start a production. This could be done by e.g. digital input. * Maximum number of reports in the batch queue. If a batch report had to be generated for the communication or printer output, the queue is limited to a maximum of ten entries. This could only happen in a case of error in communication or printer. Then the operator is informed and asked if he wanted to delete the oldest report. * The initial coldstart parameters are set to the unit of the calibration. * repair of component printout for 'B1': 'restart mode' had not been printed. * a text in the local language reformated (restart batch). * version of the application-software can be shown at Setup/Config/Vers (c) 1999 GWT Global Weighing Technologies GmbH