Changes from Rel 3.40.08 to 3.40.09 -------------------------------------- * Fix: xBPI parameter retrieve failure with WZA-Scales Changes from Rel 3.40.07 to 3.40.08 -------------------------------------- * Fix: possible fatal error after finish the display refresh Changes from Rel 3.40.06 to 3.40.07 -------------------------------------- * Add: GET_WEIGHT(ZERO_SET) * Add: method to pass standstill and error for user-wp from application Changes from Rel 3.40.05 to 3.40.06 -------------------------------------- * Fix: CCLink reads a wrong number of input byte Changes from Rel 3.40.03 to 3.40.05 --------------------------------------y * Fix: Received characters got lost by a race-condition in DEV_KEYKEY when timeout occured while received character was processed. Changes from Rel 3.40.0 to 3.40.03 -------------------------------------- * New: new function for display refresh. Once a day for 2 minutes. Changes from Rel 3.40.0 to 3.40.01 -------------------------------------- * Fix: allow rts/cts protocoll on builtin line Changes from Rel 3.30.8 to 3.40.04 -------------------------------------- * Change : added special codes for passing standstill/error in user-wp Changes from Rel 3.30.9 to 3.40.00 -------------------------------------- * New: support for Profinet I/O PR1721/36 Changes from Rel 3.30.8 to 3.30.9 -------------------------------------- * Fix: Accept WGT_USER type for GET_WEIGHT_ALIBI * Fix: Make rel_to_weight return not always the correct bool value Changes from Rel 3.30.7 to 3.30.8 -------------------------------------- * Fix: don't show DHCP parameter in X5 Changes from Rel 3.30.6 to 3.30.7 -------------------------------------- * Fix: using accessit! with ethernet communication, more than 15 fields in a table will result in a communcation error Changes from Rel 3.30.5 to 3.30.6 -------------------------------------- * Fix: rounding for NET10-Weights Changes from Rel 3.30.4 to 3.30.5 -------------------------------------- * Change: added a timeout for checking the correct function of a fieldbus card Changes from Rel 3.30.2 to 3.30.4 -------------------------------------- * Change: send always the unit to the remotedisplay Changes from Rel 3.30.2 to 3.30.3 -------------------------------------- * Change: send always the number of digits behind the decimalpoint to the remotedisplay Changes from Rel 3.30.1 to 3.30.2 -------------------------------------- * Fixed: no read from fieldbus is possible except using a ethernet/ip card Changes from Rel 3.20.0 to 3.30.1 -------------------------------------- * Fixed: PR5610/PR1713 the ethernet card PR1713/14 was not detected during power up * Fixed: If the scale has never a standstill and the communication with the OPC server * is switched on with tag ST_WGT_A than a shutdown communication will fail. * Fixed: use the 32 bit run/idle header to detect the state of the plc Changes from Rel 3.20.0 to 3.30.0 -------------------------------------- * support of 1721/37 Ethernet-IP (5510 only) * don't send special command (P) to remotedisplay Changes from Rel 3.16.8 to 3.20.0 -------------------------------------- * New implementation of the alibi memory (needs a new version of 1750) Changes from Rel 3.16.6 to 3.16.8 -------------------------------------- * Fixed : check for invalid taskstart from ethernetcard Changes from Rel 3.16.6 to 3.16.7 -------------------------------------- * Fixed : reading the BAT_REPO_HEADER table via OPC fails after running a new batch. Only the last report was visible. Changes from Rel 3.16.5 to 3.16.6 -------------------------------------- * Fixed : #1515 calculation in hysteresis correction * Fixed : #1517 memory corruption on index-errors in flashed programs Only PR1713/X5/X6: * Fixed : Setup xBPI-Scale : Show current parameter settings even if parameter change is disabled * Fixed : On specific conditions Variable-Debug in PR1750 resulted in KUW_BAD_SIZE error Changes from Rel 3.16.4 to 3.16.5 -------------------------------------- * Fixed : Overload in multirange used wrong limits * Fixed : #0001328 reading scale and application via fieldbus intermixed data if two or more plc-task used in application * Fixed : #0001322 Always reset fieldbus-slave on cpu-reset (bios-03.16.06) * Fixed : Mixing W&M-WP with none-W&M-WP didn't show wgt-unit in display (wrong hardwarecode in bios, bios-03.16.05) Changes from Rel 3.16.3 to 3.16.4 -------------------------------------- * Fixed : Display for large values on poly-range xBPI-Scales * Fixed : Diff was calculated for wrong setpoint in B8 Changes from Rel 3.16.2 to 3.16.3 -------------------------------------- * Changed : Default for xBPI taring now local * New protocoll 2-wire in serial setup Changes from Rel 3.16.1 to 3.16.2 -------------------------------------- * Fixed : Diff was calculated for wrong setpoint in B4,B5 Changes from Rel 3.16.0 to 3.16.1 -------------------------------------- * Unfixed : #0000437 FORMAT(INT,INT,INT) fix removed since it breaks to many applications the last parameter is now ignored for ANY_INT Changes from Rel 3.14.3 to 3.16.0 -------------------------------------- * New : Modifying analog-output values for customer-side meters * Fixed : #0000392 shutdown communication without runniing master corrected * Fixed : #0000368 JBUS-status showed error-count, while communication is ok * Fixed : #0000367 JBUS communication was killed, when received char while sending answer * Fixed : #0000354 WP_CONTROL('C',WGT_CONTROL#TEST_ON) returned no proper WGT_STAT * Fixed : #0000394 Entering a negative value exceeding the allowed range caused a bad display of the value after the error message. * Fixed : #0000396,0000396 Smart-Calibration: Hysterese-corrections used wrong estimated deadload * Fixed : #0000360 Negative deadload was not displayed correct in Weighingpoint/View Calibration * Fixed : minor errors in IEC #0000439 GET_RUNTIME,#0000437 FORMAT,#0000430 DUP,#0000422 ROUND, Changes from Rel 3.14.2 to 3.14.3 -------------------------------------- * Fixed : missing error exit in MAKE_WEIGHT on invalid WGT_UNIT * Fixed : #0000342 exit calibration with undo did not restore params * Fixed : #0000343 spurious interrupt when using * Fixed : #0000336 setting new calibration with specific (huge) FSDs leads to arithmetik error message * Fixed : #0000337 error message in set stepwidth not cleared * Fixed : #0000076 DisplayIt shows wrong characters if $1BH$0A was used * Fixed : #0000341 SET_WEIGHT(...,WGT_TYPE#DENS) released an internal flag) * Changed : #0000341 SET_WEIGHT(...,WGT_TYPE#USER) not blocked by reserved wpt any more Changes from Rel 3.14.1 to 3.14.2 -------------------------------------- * Fixed : #00000179 Problems deleting and download records using Accessit Changes from Rel 3.14.0 to 3.14.1 -------------------------------------- * Fixed : #00000138 Under unknown conditions DSP_INPUT did not accept '0' as input * Fixed : #00000152 and #00000153 minor display issues with audit trail Changes from Rel 3.12.0 to 3.14.0 -------------------------------------- * Added : Support for Audit-Trail from W&M BIOS PR8901/10 * Fixed : GET_WEIGHT with standstill returned bad status if scale had dimmed, but not standstill * Changed : dsp_select only uses upper line, if stop keys includes softkey * Fixed : #0000099 DB_OPEN returned bad value when handle already was opened (now returns ISOPEN) * Fixed : #0000101 A+B Weighingpoints dont need overload and minwgt to be configured * Added : GET_INFO("W&M",string) returns information about W&M-configuration of WP Changes from Rel 3.12.0 to 3.12.1 -------------------------------------- * Fixed : #0000100 Overload settings of GWT-Scale were ignored Changes from Rel 3.10.0 to 3.12.0 -------------------------------------- * Added : Support for Fieldbus-Cards on X4 * Changed : Layout of fieldbus data (internal since 3.11.6) !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! ! THIS REQUIRES APPLICATIONS COMPILED WITH PR1750 REL 2.32 OR BETTER ! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! * Fixed : #0000051 checking for I/O-Configuration always returned 'BadConf' * Fixed : Removed some Measuretime values which were left from testing (PR5510 only) * Fixed : Check Digital filter vs. Measuretime * Fixed : #0000033 Show last fault crashed on display when buffer wasn't valid * Fixed : ID for Profibus-DP Card, when switching back to 8 Byte mode * Fixed : Display of Fieldbus IDs for DPV1-Cards * Fixed : Display of BIOS-Version (1713 was shown as 5510) * Fixed : #0000055 display of entered are weights as PT * Fixed : #0000063 display of app-license on terminal Changes from rel 3.00 to 3.10 ----------------------------- BIG CHANGES TO BE LISTED: * Change : Preallocate datainstance for Application programs running on display * Added : new HMS cards: DPV1 + IBUS 2Mbit Minor changes: * Change : Update softkeys on download from PR1750 * Change : Additional checks in EAROM write to secure W&M data * Fixed : cursor down crash on terminal/weighingpoints level * Fixed : OPC Database access * BIOS : Poweron-Test made faster * Change : Version display on boot made faster * Change : Weight is dimmed if simulation activ * Change : no <...> in FORMAT(WEIGHT) if weight has dim bit * Fixed : "LUPE 10" with Step 20 * Change : added cpu-usage display in CheckIt! * Fixed : division by zero in display task results in error on next warmstart * Fixed : TON, TOF and TP had undefined outputs on negative preset times * Fixed : ReadValue.Byte6.Bit6 and WriteCommand 121dez were corrupted (since Rel 2.10) * Fixed : FSD calculation for A+B if OIML was set * Changed : internal event handling to reduce cpu load * Fixed : check fieldbus parameter after load from erased earom * Fixed : Profibus-Device-ID after switch back to 8Byte interface * Fixed : Keyklick settings after warmstart * Fixed : powerfail problem (interrupts were enabled in pwfstate when they shouldnt) * Fixed : StdScale Powerfail-Flag set on warmstart * Fixed : Detect install/remove of fieldbus-card for ColdStart * Fixed : Display of Analog-I/O did crash on front display Changes from Rel 2.xx to 3.xx ----------------------------- switch to a completely different cross-compiling environment. BIG CHANGES TO BE LISTED: * Change : Additional Firmware version for PR5510/X4 * Change : Changing parameters with [Left]/[Right] * Change : Calibration mask on terminal completely restyled * Change : weighingpoint-parameters in sec, not in M * Added : Calibration by entering loadcell data (as known from PR1710/11/20) * Change : Printout of calibration data completely restyled * Change : Printout of configuration now includes all version strings * Change : Added support for 1721/14 1721/24 Ethernet cards * Removed : PR1721/0x DeviceNet (use PR1721/1x or /2x instead) * Removed : PR1721/0x CAN-Bus * Added : Fieldbus-Interface for PR1721/1x and /2x can be extended beyond 8 Bytes * Added : Enhanced debug support for PR1750 including - faster online variables - breakpoints and singlestep - I/O controlling (used in CheckIt!) Minor changes: * Change : Speedup of WEIGHT arithmetics * Change : SPM allocated at compiletime * Change : Force system restart on options changed * Change : disable simulation while calibration active * Change : disable simulation if cal jumper closed * Added : Print last fault. * Added : WP-Simulation control from IEC-61131 * Added : Online variable debug for flashed programs * Added : IEC-61131 : STR2STRUCT * Fixed : display of negative deadload in cal-view * Fixed : Remove breakpoint on inactive recipe line * Fixed : switch cursor temporary off due very slow updates of ExTec-Terminal * Fixed : operating at was not shown if selected serial card was removed * Fixed : plc restart problem on powerfail * Fixed : database access via OPC * Fixed : DEV_OPEN did not return any errors * Added : va and vb telegram Changes in BIOS to 3.xx ----------------------- * Added : Flash over Ethernetcard (FlashIt! 2.3x required) Changes from Rel 2.20.2 to 2.XX -------------------------------------- * Fixed : no download for earom possible if the cal jumper is closed Changes from Rel 2.20.1 to 2.20.2 -------------------------------------- * Fixed : the OPTION statement will return PR1721 if the new fieldbuscards (HMS) are inserted. * Fixed : Set and remove breakpoints from PR1740 will crash. Changes from Rel 2.20.0 to 2.20.1 -------------------------------------- * Fixed : accept a cancel from Recoverit! during up/download. added timeout for receiving, task finish after 1 minute of inactive communication * Fixed : DSP_INPUT on string crashed, when content of last string result was longer than the edited string variable * Fixed : DSP_INPUT on TimeOfDay and DateAndTime value check fixed Changes from Rel 2.12.0 to 2.20.0 -------------------------------------- * Fixed : STRING_TO_DATE on 1980..1999 return bad date * Fixed : EQUAL of struct nearly always returned false, if struct had arrays of BOOL inside. * Change : DBASE now ignores fraction of seconds in TIME_OF_DAY and DATE_AND_TIME to be more compatible with PC databases Changes from Rel 2.10.1 to Rel 2.10.x: -------------------------------------- * Added : On commandline "SHOW DEVSTAT /R /C" * Added : Show last fault now displays timestamp of error * Fixed : Added refresh timeout for Ex-Terminal * Fixed : Below zero check for taring W&M weighingpoints * Added : on startup all display-segments are shown for visual test * Added : Database now has a BCC * Added : Show Sensitivity in calibration * Change : External Weighingpoint have error 15 on serialnumber mismatch * Change : xBPI-Scale now has an option to tare local * Fixed : on coldstart recipe lines was allocated twice * Fixed : Crash in DBASE calling system when timeout occurs * Fixed : DBASE internal bug on RECORD with a BOOL as last element * Fixed : Misleading error message for PR1740 when no memory while downloading recipe * Fixed : If change of recipe lines not possible, restore old values * Fixed : CRC16 didn't setup optional parameter CRC * Added : GET_WEIGHT with tenfold resolution * Added : W&M Mode NSC * Fixed : WEIGHT_TYPE returned internal numbers instead of WGT_TYPE# NOTE: this requires an updated version of ALIBI-LIB * Fixed : doing a DB_MODIFY after a failed DB_SEEK crashed the database (Thanks to E.W. for the report) Changes from Rel 2.10 to Rel 2.10.1: ------------------------------------ * Added : Parameter tare local for xBPI * Added : System checks stack once more * Change : Default SW-Config Reports to NONE * Fixed : CodeFault, when using recipe with textparameter on dosing FBs without tolerance * Fixed : DSP_SELECT hangup, when using Delete key on PC-Keyboard Changes from Rel 2.02 to Rel 2.10: ---------------------------------- * Added : Free assignment of weighingpoints * Added : Support for HMS * Fixes : Fixes in DIOS-Master for HMS-Slaves Changes from Rel 2.00 to Rel 2.02: ---------------------------------- * Added : Support for NiceLabelExpress * Added : Seperate BIOS for X5 keyboard * Added : Download protected by cal-jumper * Added : Support for different BIOS in firmware * Added : Show flash date and user if authorized * Updated : Support for ExTec * Updated : DIOS Master (please use modified PR1713/13) * Change : Allow 10 open DB-Handles for IEC Task * Change : No Production report by default * Bugfix : DB_COPY * Bugfix : FixTare for xBPI-Scale * Bugfix : enter 9999 for USINT * Bugfix : DEV_INPUT on terminal got no default timeout * Fixed : Setpoint=0 for B6 * Fixed : Input of WEIGHT on display * Fixed : IO-Check only for cards used by plc-task * Fixed : Clear DIOS Outputs on powerfail Changes from Rel 1.12 to Rel 2.00: ---------------------------------- * Saturn * Subrecipe * Remote Device * Interbus-S G4 Master * Software download protection * DUST Protocol * xBPI Scale * Liquid counter * Application License Changes from Rel 1.10 to Rel 1.12: ---------------------------------- * PR1713/14 Ethernet supported * New configuration concept on operating terminal * NTEP Calibration counters * JBUS/ModBus Protocol * US/German PC Keyboard * Online I/O Monitor on front-display * Free communication programming in IEC1131 * Bugfix in DeviceNet (bad idle telegram) Changes from Rel 1.08 to Rel 1.10: ---------------------------------- * Device-Net supported as slave * Bugfix in PR1721 as Interbus-S slave * Bugfix in XON/XOFF protocoll * Bugfix in RS485 control * Minor fixes in configuration levels (Fieldbusconfig as own level) Changes from Rel 1.06 to Rel 1.08 (not published): -------------------------------------------------- * Support for new hardware options (1713/08, 1713/17, 1713/15, 1713/07) * Bugfixes in DB_FIND and DB_COPY * Bugfix in read of boardnumber Changes from Rel 1.06 to Rel 1.06.4: ------------------------------------ * W&M-Printer protocoll fixed * SET_WEIGHT with negative FixTare fixed * setting address of PR1720 external WP fixed * MAKE_WGT_TO_REAL fixed Changes from Rel 1.04 to Rel 1.06: ---------------------------------- * Interbus-S ST-Modules supported by DIOS * DIV/0 Error with certain calibration fixed * Additional parameter passing for self-written batching FBs fixed Changes from Rel 1.02 to Rel 1.04: ---------------------------------- * DIOS (PR1713/13) now works as specified Note: PR1750 Rel 1.60 SP1 required for DIOS Changes from Rel 1.00 to Rel 1.02: ---------------------------------- * Inputs of PR1713/12 returned inverted data into %IXn.m * Operator Task did not properly switch to other device after change in software parameters. (c) 1999 GWT Global Weighing Technologies GmbH Changes from Rel 2.10.1 to Rel 2.10.x: -------------------------------------- * change : updated for PR1713/02 keyboard * added : $80 on display is set to euro-sign * change : message for low power supply